The Regulatory Environment of Pharma Companies: 
GMP & GDP Guidelines

Companies that research, produce, store, transport or sell pharmaceutical products are subject to regulatory requirements. The most common known practices are:

  • Good Manufacturing Practices (GMP): GMP are the practices required in order to conform to the guidelines recommended by agencies that control the authorization and licensing of the manufacture and sale of food and beverages, cosmetics, pharmaceutical products, dietary supplements, and medical devices. These guidelines provide minimum requirements that a manufacturer must meet to ensure that their products are consistently high in quality, from batch to batch, for their intended use.
  • Good Distribution Practices (GDP): Good distribution practice (GDP) describes the minimum standards that a wholesale distributor must meet to ensure that the quality and integrity of medicines is maintained throughout the supply chain.

The laws and regulations are specific to each country and typically include a national or international authority like the FDA (Food and Drug Administration) in the United States); EU (European Union) in Europe; or Swissmedic (in Switzerland), all coordinated by the ICH (International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use).

In addition to official regulations, there are a number of important associations issuing guidance documents supporting and detailing the regulations and their application in specific situations. Some of the most influential organizations relevant to the pharmaceutical supply chain industry are the ISPE (International Society for Pharmaceutical Engineering), the USP (United States Pharmacopeia), the PDA (Parental Drug Association) and the WHO (World Health Organization). The regulatory framework is therefore a living organism which changes almost daily with new laws becoming effective and new guidance documents being published.

GMP GDP

GMP vs. GDP – what are the differences?

From a drug supply chain perspective, the cornerstones of the regulatory framework are the Good Manufacturing Practice system (GMP) and the Good Distribution Practice system (GDP). These are often referred to jointly as GxP. While GMP lays its focus on activities around manufacturing (including testing, release & storage), GDP focuses on the distribution including transportation, storage and wholesale of pharmaceuticals products. Both, GMP and GDP aim to increase public health by ensuring the product quality. 

In a nutshell

If you store or transport pharmaceutical products you have to comply to GMP and GDP guidelines. Thus, you must ensure that:

What is Title 21 CFR Part 11?

If a company transports pharmaceutical products and wants to comply to GDP guidelines it must store and transport the products in qualified facilities, transport containers and networks. The temperature sensors must be calibrated and the product release must take place in a qualified and complaint system. What does compliance in combination with a temperature monitoring solution mean? In this chapter, we will explain compliance from a Cold Chain perspective.

“Title 21 CFR Part 11” is the part of the Title 21 of the Code of Federal Regulations written by the United States Food and Drug Administration (FDA). Title 21 contains regulations on electronic records and electronic signatures. Part 11 defines the criteria by which electronic records and electronic signatures are considered trustworthy, reliable, and equivalent to paper records to ensure GxP compliance.

A monitoring solution which stores electronic records which are critical to patient safety must be in compliance to Title 21 CFR Part 11. In order to do so it is important to understand the main risks. 

How Does Title 21 CFR Part 11 Apply to a Cold Chain Monitoring Solution?

Electronic data could be deleted, accidentally modified or intentionally modified. Title 21 CFR Part 11 defines criteria by which electronic data is trustworthy, reliable and equivalent to paper records and handwritten signatures executed on paper. If you follow those rules your electronic records will be complete, intact, maintained in the original context, and geared towards compliance. In the context of a Cold Chain monitoring solution this means the following:

Complete Data – Monitoring temperature with the help of sensors, a communication bridge and the software solution, one of the main challenges is the completeness of data. Mechanisms need to be in place to ensure compliance so that no data is lost on the way from the wireless sensors through the communication bridge to the monitoring software. Therefore, in case of a disconnection between the sensors and the radio bridge or the cloud storage, data must be buffered in the sensors until the cloud confirms that the connection has been re-established and the data has arrived. 

When monitoring data in a Cold Chain environment the completeness of the data is THE main concern and cause for problems. Therefore, the Cold Chain database should include mechanisms to mitigate the following risks:
  • Somebody has forgotten to equip the pallet with a sensor
  • The sensor was started early or stopped late
  • The raw data file from the USB data logger was not uploaded
  • The real-time logger lost connection and data never arrived

Intact Data – Although the risk for accidental or intentional modification is minimal, the integrity of data in a measurement chain can only be achieved by encrypting the data all the way from the measuring wireless sensor through the communication bridge (LPWAN network or email) to the cloud. Once the data has arrived in the software it is important that no raw data can be deleted or modified. No user should not be able to change the raw data, however it is possible to add certain types of additional information. For example, in order to add an interpretation of the data, certain comments or acknowledgements about the raw data can be added to the system. Furthermore, in order to create selective views on the raw data, reports can be created and exported.

Maintaining Electronic Data in its Original Context – Keeping the data in one single source on a central cloud infrastructure ensures that it is kept in its original recorded context and the risk of misinterpretation is therefore eliminated. Warnings, alarms, and reports should always refer to the unique sensor name, event number, and time stamp.

The Audit Trail: 
Compliance in User Management and Authentication

There are many rules to follow when it comes to compliance in user management. Every user with access to the solution must be identified by a unique username and password and must have a clear role and rights. Additionally, every action taken by the user in the system must be identified and tracked. When conducting critical operations, such as the acknowledgement of an alarm, the user even needs to confirm his action by inserting his password a second time. In order to avoid unauthorized access it is important to implement a time-out mechanism in case the user is not taking action for a longer time period.

The result tracking functionalities mentioned above is a complete audit trail aligned with compliance. It answers the questions: who has done what and why? Technically, the audit trail keeps track of every single automated event the system is generating and every single manual task a user is performing. So, regardless from which perspective one takes a look into the system, a full audit trail could be:

  • Sensors: Timeline of all events on a sensor like measurement values, status, setting changes, warnings, alarms, and acknowledgments
  • Warnings and alarms: Time stamps, statistics, who has commented on what, who has acknowledged something, and when
  • Reports: Sensor names, timeline, and the user that created the report

In a Cold Chain database the question of audit trail is much more complex than for a solution monitoring rooms and equipment. Why? Because there are many more participants included.

  • High battery consumption resulting in bulky devices and short battery life
  • Lack of standardization in roaming and SIM-card handling
  • Lack of an international standard for airline approvals

As a result, those devices were dedicated to a local trucking market or to the maritime market transmitting values from ocean containers to proprietary antennas on ships. One of the first companies to launch a true international real-time temperature and position logger was a freight express company operating a fleet of aircrafts. The price for one device was higher than 1000 USD per device – not including the connectivity and roaming.

Later devices used the 3G/4G network, which meant a significant reduction of battery consumption. Powered by lithium batteries, they achieved a battery life of 30 or more days. To get airline approval, they had to be multi-sensor devices monitoring all kinds of parameters like pressure, acceleration and light. Using lithium batteries (other than button cells) however resulted in a new problem. In 2017, IATA released a new regulation limiting the number of lithium cells per handling unit and also requested declaration of each data logger sensor used in a shipment. This was a draw back again and one of the reasons why real-time temperature loggers did not break through so far.

Automated Events in the Audit Trail

A temperature monitoring system typically executes the following different automated mechanisms and workflows:

  • monitoring the system availability and performance (to trigger a system warning)
  • monitoring the sensors (battery status, wireless connection, validity of the delivered data to trigger sensor warning)
  • measuring, storing and evaluating temperature values, and matching them with the defined limits to trigger high/low temperature warnings and alarms (For further information see the section below on "How to Deal with Temperature Excursions")
  • monitoring all settings and setting changes

Manual Tasks in the Audit Trail

In addition to automated events, the system must keep track of every single manual task a user performs including the time stamps of each task. The following manual events could be tracked:

  • Who is logged into the system and what are the roles and rights of this individual?
  • Who has logged in/out, and at which times?
  • Who has changed settings and what were the settings like before and after the change?
  • Who has commented or acknowledged a warning or an alarm?
  • Who has generated a report?

What to Ensure in An Audit Trail
When Monitoring Products in Transit?

In a Cold Chain database, the question of an audit trail is much more complex than for a solution monitoring rooms and equipment. Why? Because there are many more participants included:

  • Who owns the system: Product owner, e.g. Market Authorization Holder (MAH) is responsible for the system
  • Who configures the individual sensor: Many different warehouse employees at different sending sites.
  • Who views and comments on temperature deviations: Many different parties can be involved including the warehouse recipient, warehouse sender, logistics service providers, quality assurance recipient, and quality management sender.

The Cold Chain database must keep an audit trail aligned with compliance and verify who has done what, and why? Yet even more important is to limit the user rights, preventing any intended or unintended changes which are not absolutely necessary to perform the specific process in the given situation. A full Cold Chain audit trail could be:

  • Acceptance Criteria (stability budget): What set of stability budget is used, who has released this set, and when?
  • Configuration of Shipment and Data Logger: Which system (or person) has configured the specific shipment and defined the chosen configuration and link to the stability budget?
  • Temperature Data: Measurement values, status, setting changes
  • Warnings and Alarms: Who has been informed of a warning or alarm, and by when?
  • Comments, Reassessments and Releases: Who has commented on a shipment, performed a manual or automated re-assessment, and finally released the product?
  • Reports: Sensor ID, shipment information, and the user that created the report

IATA, TCR and the 
CEIV Pharma Program

The International Air Transport Association (IATA) has recognized that the pharmaceutical industry tries to avoid air transportation whenever possible. “A majority of all temperature excursions that occur happen while the package is in the hands of airlines, airports and their contractors.” More than 15 years ago, IATA initiated the Time and Temperature Working Group (TTWG) that developed the Temperature Control Regulations (TCR), a guide designed to enable stakeholders involved in the transport and handling of temperature sensitive products to meet the requirements of the pharmaceutical industry. This guide raised the awareness of these issues within the entire logistics industry. The group also introduced the “Time & Temperature Sensitive” label, which still today remains a well-known standard.

However, IATA has recognized that a label was not enough and created the Center of Excellence for Independent Validators in Pharmaceutical Logistics (CEIV Pharma). The CEIV Pharma certification program aims to support the air cargo supply chain in achieving pharmaceutical handling excellence and increase safety, security, compliance and efficiency by the creation of this globally consistent and recognized pharmaceutical product handling certification. Airports, trade lanes, service providers, and entire networks can now be certified by training personnel, improving equipment, and introducing checklists and processes.

How to Qualify a Data Logger and Database

GMP and GDP clearly require qualifying all equipment used to produce, store, and transport temperature sensitive pharmaceuticals. This obviously includes data loggers. As a pharmaceutical company using a data logger and/or a cold chain database, you need to proof that it fulfills the intended purpose.

Qualification is the documented proof by the Market Authorization Holder (MAH), that the Cold Chain monitoring solution fulfills its intended purpose: documenting a release decision.

The company using the Cold Chain monitoring solution must perform the qualification job itself and individually on the specific process. The qualification documentation of the Cold Chain monitoring company is a popular target during FDA audits. Qualification of a Cold Chain monitoring solution in a specific situation can be kept simple, if the supplier qualifies all elements of the solution (i.e. hardware, software, services) beforehand, and provides profound documentation to support it. Although qualification is the better term, this activity is often called “component validation.”

Each component used in a Cold Chain monitoring solution must be validated/qualified by the supplier. They must provide documented proof that each component fulfills its intended purpose. 

Comprehensive qualification support packages provided by data logger vendors include:

  • URS template describing all functionalities
  • High level risk analysis rating the risk (probability, severity and detectability) and mitigation measures
  • Validation plan and validation report summarizing referring versions and documents
  • Qualification template for an OQ

The supplier typically provides guidance during the qualification and is open for audits. During audits, the detailed V-Model documents can be inspected.

How to Automate GxP Refrigerator and Storage Monitoring

To automate refrigerator and storage monitoring in a GxP environment, replace manual temperature checks with calibrated sensors that record conditions continuously and send the data to a validated monitoring system. The system compares every reading to defined limits, alerts the right people when conditions drift, and records every action in a secure audit trail that supports 21 CFR Part 11 and EU GMP Annex 11.

The sections above explain what regulators expect from a compliant monitoring system. This section shows how pharmaceutical and laboratory quality teams put those requirements into practice for pharmaceutical storage: refrigerators, freezers, ultra-low temperature (ULT) freezers, cold rooms and warehouses.

Why Manual Refrigerator Checks Fall Short in GxP Environments

Many sites still read a min/max thermometer once or twice a day and record the values on paper. The method is simple, but it leaves gaps that are hard to defend during an inspection:

  • Blind spots between readings. A refrigerator can drift out of range overnight or over a weekend and recover before the next check, leaving no record of how long product was exposed.
  • No real-time response. If nobody is on site, a failed compressor or an open door can go unnoticed until product is already affected.
  • Data integrity risk. Handwritten logs are prone to transcription errors, missed entries and late entries, which makes it harder to show that records meet ALCOA+ principles.
  • Heavy review workload. QA teams spend time checking, signing and filing logs instead of investigating real deviations.

Automated storage condition tracking closes these gaps by recording at fixed intervals around the clock and flagging deviations as they happen.

What Automated Monitoring in GxP Environments Includes

A GxP-ready temperature monitoring system is more than a sensor with an alarm. Look for these core capabilities:

  • Continuous data capture. Calibrated sensors record temperature (and humidity or other parameters where needed) at a set interval, 24/7 and buffer data locally if the connection drops. The result is a complete, gap-free record of storage conditions.
  • Automated alerts. Every reading is checked against warning and alarm limits. Notifications go out by email, SMS or on screen, with escalation if no one responds, so teams can act before product quality is affected.
  • Audit trail. The system records who did what, when and why, including setting changes, alarm acknowledgments and comments. This supports data integrity requirements under 21 CFR Part 11 and EU GMP Annex 11.
  • Electronic records and signatures. Unique user accounts, role-based permissions and password re-entry for critical actions make electronic records trustworthy and equivalent to paper records.
  • Dashboards and reports. A dashboard shows the current status of every monitored unit and periodic and excursion reports are generated automatically. QA gets a quick status check and inspection-ready documentation.
  • Calibration and qualification support. Calibrated sensors with certificates, plus validation documentation for hardware and software, demonstrate that the system is fit for its intended use.

For more on audit trail requirements, see "The Audit Trail: Compliance in User Management and Authentication" above.

Step by Step: How to Automate GxP Refrigerator Monitoring

  • Define scope and requirements. List every refrigerator, freezer, ULT freezer, incubator, cold room and storage area that holds GxP-relevant product or samples. Record the required range for each (for example, 2 °C to 8 °C), what is stored there, and the risk if conditions are lost. Capture this in a user requirements specification (URS).
  • Map storage units and choose sensor locations. Temperature mapping identifies hot and cold spots and shows where a monitoring sensor best represents product conditions. Larger spaces such as cold rooms and warehouses usually need several monitoring points. According to ELPRO GxP expert Stephanie Punter, "A sensor tells you what’s happening where that sensor is. That’s why temperature mapping is critical.”
  • Select sensors and connectivity. Match the sensor to the application: internal probes for standard refrigerators and rooms, external probes for freezers, ULT freezers and cryogenic storage. Choose a connection that suits your site, such as a wireless radio network, LAN or LPWAN. Confirm that sensors store data locally during interruptions and that each one comes with a traceable calibration certificate.
  • Configure alarm limits and escalation. Set warning and alarm limits based on product requirements and mapping results, add alarm delays where appropriate and define who is notified, how and in what order. See the alarm design guidance below.
  • Set up user management and the audit trail. Create individual user accounts, assign roles based on what each person needs to do, and require password confirmation for critical actions such as acknowledging an alarm.
  • Qualify and validate the system. Document installation, operational and performance qualification (IQ, OQ, PQ) using a risk-based approach such as GAMP 5. Ask your supplier for validation support documents to reduce the effort. See "How to Qualify a Data Logger and Database" above.
  • Write SOPs and train your team. Define how alarms are acknowledged, who investigates, how excursions are documented, and when product is quarantined or released. See "How to Deal with Temperature Excursions?" below.
  • Review, report and maintain. Schedule periodic reports, review alarm history for trends, test alarms regularly, recalibrate sensors on a defined schedule, and include the system in your periodic review program.

Automated Alerts for Storage: Designing Alarms Teams Act On

Automated alerts only protect product if the right person sees them and responds. Too few alerts put product at risk. Too many lead to alarm fatigue, where staff start to ignore notifications.

“Collecting the data is usually the easy part. Knowing what to do with it is where companies can struggle."

Stephanie Punter, GxP Team Lead and Deputy Quality for the Americas at ELPRO


Effective alarm design includes:

  • Two-level limits. A warning limit signals that conditions are drifting so staff can act early. An alarm limit signals a deviation that requires documented action. For example, a 2 °C to 8 °C refrigerator might have warnings at 3 °C and 7 °C and alarms at 2 °C and 8 °C.
  • Alarm delays. A short delay prevents nuisance alarms from routine door openings while still catching sustained deviations. Base the delay on how quickly the unit and its contents warm or cool.
  • Technical alarms. Alert on sensor disconnection, low battery and lost communication as well as temperature, so a silent sensor is never mistaken for a stable one.
  • Escalation chains. If the first contact does not acknowledge an alarm within a set time, notify the next person. Plan coverage for nights, weekends and holidays.
  • Documented acknowledgment. Each acknowledgment should capture the user, the time and a comment explaining the cause and the action taken.
  • Regular alarm testing. Test notifications periodically to confirm that contact details are current and messages arrive.


Scaling from a Few Refrigerators to a Multi-Site Storage Network

Many organizations start with a few units in a lab or pharmacy, then expand to cold rooms, warehouses and additional sites. Planning for scalable deployment early prevents rework later:

  • Standardize configurations. Use templates for alarm limits, measurement intervals, and notification groups so every site follows the same rules.
  • Use a consistent naming structure. Organize sensors by site, building, room and unit so reports and audit trails are easy to follow.
  • Centralize visibility, localize response. QA can review status across all sites in one system, while local teams receive the alarms they are responsible for.
  • Choose a platform that can grow. Cloud-based systems make it easier to add sensors and sites without new on-site servers. On-premises systems may better suit organizations with strict IT requirements.
  • Plan for integration. An API connection lets monitoring data flow into other quality or enterprise systems.
  • Keep validation manageable. Use change control and a risk-based approach so adding units or sites does not mean revalidating the entire system.

Common Mistakes to Avoid

  • Placing sensors without mapping data, which can miss hot or cold spots.
  • Setting alarm limits equal to product limits with no warning level, which leaves no time to react.
  • Sending every alarm to a shared inbox that nobody owns.
  • Ignoring technical alarms such as low battery or lost connection.
  • Letting calibration certificates lapse.
  • Treating validation as a one-time project instead of maintaining it through change control.

How ELPRO Supports Automated GxP Storage Monitoring

ELPRO combines calibrated ECOLOG-PRO sensors for rooms, refrigerators, freezers, ULT freezers and cryogenic storage with elproMONITOR Cloud software for continuous data capture, automated alerts, audit trails and reporting. ELPRO's GxP services team also supports temperature mapping, calibration and qualification, so quality teams can plan, validate and expand their monitoring with one partner.

Planning to automate monitoring for your refrigerators, freezers, or storage areas? Talk with an ELPRO specialist about sensor placement, alarm design and qualification for your site.

How to deal with Temperature Excursions?

GMP and GDP standards define that pharmaceutical products must be stored and transported according to the required temperature conditions mentioned on the drug label to ensure compliance. Every excursion from these temperature conditions must be documented. The monitoring system should support the user in creating automated excursion reports to which the user can still add certain information. The following procedure gives an example on which questions a Quality Manager should ask, once a temperature excursion has occurred. 

Excursion Report


ALARM GOES OFF

A temperature excursion triggers an alarm. The alarm can be seen on the sensor itself or the dashboard display and can be sent out via email or SMS text containing an excursion report with the following information:

  • Where did the alarm go off? Which facility, container or sensor had an excursion?

  • When did the temperature excursion occur and when were the drug label conditions re-established?

  • How long has the product been exposed to temperatures outside the drug label conditions?

  • What was the highest/lowest temperature measured?

Manual Information to be Added by a User to the Temperature Monitoring System

  • Affected Product? Which product, batch or pallet has been potentially affected?
  • Risks? Is it likely that the core temperature of the product has been affected, thus damaging the product?

  • Severity? Is there sufficient stability budget left to justify a release of the product or is a product recall necessary?

  • Corrective actions needed? What is the cause of the temperature excursion and does it have to be corrected? Do people need to be informed about the findings?

  • Preventive Actions needed? In case of high-risk and/or repetitive errors, which preventive actions can be performed in order to avoid a repetition of the event? Are changes implemented?

The Dashboard

Why is a Dashboard Important?

A dashboard gives a brief overview on the current status of each sensor. The sensors can be grouped in a meaningful way or placed on top of a floor plan to illustrate their physical location. The dashboard should show the currently measured value, show the alarm status, and give further meaningful information on the technical status of the sensor. The benefits of a dashboard are:

  • Clear entry screen into the software and easy navigation from the dashboard
  • Quick overview screen for operators to see whether the production is running smoothly or not
 
ELPROCloud_Screen_StarterKit_190917_web-1

Why is Periodic Reporting Important?

Besides a clear alarming mechanism, it is vital to have periodic reporting on all sensors on a system. Reports can serve different purposes and therefore, contain different content. If the report serves as an archive of data, it should be in compliance with the ISO standards for long-term archiving. If the report is sent to customers, it might be beneficial to combine various sensors together, providing a comprehensive overview of the customer's project. Examples of regular reports may include:

  • Monthly reports for each sensor (for archiving purposes)
  • Weekly reports of various sensors combined (for customer reports)
  • Daily reports for each sensor (for data exports to a batch system)

How is Data Archived?

Archiving is not clearly defined in GxP regulations and is left open to interpretation. Many people have the unrealistic idea that once data is archived, it should be available forever in the same way it was generated. Data archiving is the process of "moving data that is no longer actively used to a separate storage device for long-term retention. Archive data consists of older data that remains important to the organization or must be retained for future reference or regulatory compliance reasons.” As a result, "archive data" has a different form than "process data."

Process Data

Process data is “fresh data” which is used to execute business decisions (e.g. data of a product, mean kinetic temperature calculation of a stability study). The service provider must ensure that, for two years, process data is available electronically for visualizations (e.g. zoom, overlay); statistics (e.g. calculate MKT); reports (e.g. release decision); and exports of the data (e.g. to a higher batch management system). Furthermore, it must be possible to add comments related to the data in the system.

Archive Data

After the first two years, the data is typically not needed in business processes anymore and its location and form will be changed to archive data. The service provider must ensure that archive data is available for at least 10 years and fulfils the following requirements:

  • Naming conventions clearly labeled (e.g. "monthly report Sensor A")
  • Data must be stored as a record in a readable form. For example the "PDF/A" format, which follows the ISO 19005 standards for archived documents
  • Data must be stored in a secured data archive

Frequently Asked Questions About GxP Compliance in Monitoring Solutions

How can I automatically monitor refrigerators and storage in GxP environments?

Install calibrated sensors in each refrigerator, freezer, or storage area and connect them to a validated monitoring system. The system records conditions continuously, sends automated alerts when readings move outside defined limits, and keeps an audit trail of every reading and user action. Place sensors based on temperature mapping results, and qualify the system before use.

Is automated temperature monitoring required for GxP compliance?

GxP regulations generally do not require a specific technology. They require that storage conditions are controlled, monitored and documented, that deviations are detected and investigated, and that electronic records are trustworthy. The EU GDP Guidelines, for example, call for alarm systems that alert staff to excursions from defined storage conditions. Automated monitoring is a common way to meet these expectations consistently, especially when storage must be covered around the clock.

What makes a refrigerator monitoring system GxP compliant?

A GxP-compliant system uses calibrated sensors, records data continuously without gaps, protects records from alteration, maintains a complete audit trail, and controls access with unique user accounts and defined roles. It must also be qualified for its intended use and support the electronic records requirements of 21 CFR Part 11 and EU GMP Annex 11.

How often should a GxP monitoring system record temperature?

Set the measurement interval through a risk assessment that considers how quickly the unit can drift out of range and how sensitive the product is. Intervals of a few minutes are common for refrigerators and freezers. Shorter intervals give better resolution when investigating an excursion.

What happens to monitoring data if the network connection is lost?

In a well-designed system, sensors store readings locally during an interruption and transmit them once the connection returns, so the record stays complete. The system should also send a technical alarm when a sensor stops communicating.

How often should monitoring sensors be calibrated?

Define calibration frequency in your procedures based on risk and each sensor's performance history. Annual calibration is common practice. Use calibration that is traceable to national or international standards, such as calibration from an ISO/IEC 17025 accredited laboratory.

Can one system monitor refrigerators, freezers, and warehouses across multiple sites?

Yes. A scalable monitoring system can combine different sensor types and locations in one platform, with central dashboards for QA and local alarm routing for site teams.

Contact Our Compliance Monitoring Specialists Today

Ensure your GxP processes run smoothly by relying on ELPRO's experienced project team. Our experts will support you from planning to implementation, helping you to increase efficiency, meet regulatory requirements and maintain the highest quality standards. Let's talk about your next project.

Newsletter-Sign Up ELPRO News

ELPRO will use the information provided in this form to keep in touch with you and to send you updates and marketing information by e-mail.

 

Symb_Digital_Call_Laptop_Conference_600x314