| Datalogger ECOLOG
TH1 |
Part No.: 2423 |
|
|
| |
|
 |
Connection for 1 integrated
(-35°C ..+55°C; 0% ..+100% rH) orup to 2 external humidity
and temperature probes (-35°C ..+70°C; 0%..100% rH) orand
second temperature probe
(-50°C..+140°C) |
 |
Calibrated, exchangeable
humidity and temperature probes (Part No.: 3087 or 3087-B) |
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
Key pad with 4 keys, external
start, alarm reset, measured value and alarm scroll |
 |
1 digital input |
 |
DB15 multifunction connection
with alarm output and RS232 |
 |
Direct printout of measured
values and alarm data at printer |
 |
|
|
 |
Ecolog TH1 with white housing |
Part No.: 2423-W |
 |
Ecolog TH1 EEX with approval
for EEX zone 1 |
Part No.: 2423-Ex |
 |
|
|
|
|
 |
|
|
|
|
|
 |
 |
|
|
|
 |
| |
 |
|
| Datalogger ECOLOG
TH2 |
Part No.: 2426 |
|
|
| |
|
 |
For 2 external, calibrated
and exchangeable humidity and temperature probes -35°C ..+70°C;
0% ..100% rH (Part No.: 3087) |
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
Key pad with 4 keys, external
start, alarm reset, measured value and alarm scroll |
 |
1 digital input |
 |
DB15 multifunction connection
with alarm output and RS232 |
 |
Direct printout of measured
values and alarm data at printer |
 |
|
|
 |
Ecolog TH2 with white housing |
Part No.: 2426-W |
 |
Ecolog TH2 EEX with approval
for EEX zone 1 |
Part No.: 2426-Ex |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
| Datalogger ECOLOG
TN2 |
Part No.: 2420 |
|
|
| |
|
 |
For 2 NTC probes -50°C..+140°C
/ -35°C..+55°C (with integrated temperature probe) |
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
DB15 multifunction connection
with with alarm output and RS 232 |
 |
External start / alarm
reset / InPos recognition (with special connectors) |
 |
No keys, no direct printout |
 |
|
|
 |
Ecolog TN2 with white housing |
Part No.: 2420-W |
 |
Ecolog TN2 EEX with approval
for EEX zone 1 |
Part No.: 2420-Ex |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
| Datalogger ECOLOG
TN3-P |
Part No.: 2420-P |
|
|
| |
|
 |
For 3 NTC probes -50°C..+140°C
/ -35°C..+55°C (with integrated temperature probe) |
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
DB15 multifunction connection
with alarm output and RS232 |
 |
External start / alarm
reset / InPos recognition (with special connectors) |
 |
Automatic printout of
measured values at printer |
 |
No keys |
 |
|
|
 |
Ecolog TN3-P with white housing |
Part No.: 2420-PW |
 |
Ecolog TN3-P EEX with
approval for EEX zone 1 |
Part No.: 2420-PEx |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
| Datalogger ECOLOG
TN4 |
Part No.: 2421 |
|
|
| |
|
 |
For 4 NTC probes -50°C..+140°C
|
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
Key pad with 4 keys |
 |
External start, alarm
reset, measured value and alarm scroll |
 |
2 digital inputs |
 |
DB15 multifunction connection
with alarm output and RS232 |
 |
Direct printout of measured
values and alarm data at printer |
 |
|
|
 |
Ecolog TN4 with white housing |
Part No.: 2421-W |
 |
Ecolog TN4 EEX with approval
for EEX zone 1 |
Part No.: 2421-Ex |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
| Datalogger ECOLOG
TN4-L |
Part No.: 2422 |
|
|
| |
|
 |
For 4 NTC probes -50°C..+140°C
with LEMO connector |
 |
Memory capacity for 64,000
measured values |
 |
Large display with alarm
information |
 |
Key pad with 4 keys |
 |
External start, alarm
reset, measured value and alarm scroll |
 |
2 digital inputs |
 |
DB15 multifunction connection
with alarm output and RS232 |
 |
Direct printout of measured
values and alarm data at printer |
 |
|
|
 |
Ecolog TNç-L with white housing |
Part No.: 2422-W |
 |
Ecolog TN4-L EEX with
approval for EEX zone 1 |
Part No.: 2422-Ex |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
|
| |

 |
|
| Datalogger ECOLOG
TP2 or TP4-L |
|
|
|
| |
|
 |
TP2: For 2 PT100 probes
in 4-wire system at DB15 connector |
Part No.: 2425-2T |
 |
TP4-L: For 4 PT100 probes
in 4-wire system at LEMO connector |
Part No.: 2425 |
 |
PT100 probes :-200°C..+550°C |
|
 |
Memory capacity for 64,000
measured values |
|
 |
Large display with alarm
information |
|
 |
Key pad with 4 keys |
|
 |
External start, alarm
reset, measured value and alarm scroll |
|
 |
1 digital input |
|
 |
DB15 multifunction connection
with alarm output and RS232 |
|
 |
Direct printout of measured
values and alarm data at printer |
|
 |
|
|
 |
Ecolog TP2 with white housing |
Part No.: 2425-2TW |
 |
Ecolog TP2 EEX with approval for EEX zone 1 |
Part No.: 2425-2TEx |
 |
Ecolog TP4-L with white housing |
Part No.: 2425-W |
 |
Ecolog TP4-L EEX with
approval for EEX zone 1 |
Part No.: 2425-Ex |
 |
|
|
|
|
 |
|
|
|
|
| |