D | E | F  
ECOLOG
ECOLOG TH1 | TH2 | TN2 | TN-3P | TN-4 | TN4-L | TP2 | TPL-4
Sensors | Accessories | Datasheets | Software
  Datalogger ECOLOG TH1  
Datalogger ECOLOG TH1 Part No.: 2423
 
   
Connection for 1 integrated (-35°C ..+55°C; 0% ..+100% rH) orup to 2 external humidity
and temperature probes (-35°C ..+70°C; 0%..100% rH) orand second temperature probe
(-50°C..+140°C)
Calibrated, exchangeable humidity and temperature probes (Part No.: 3087 or 3087-B)
Memory capacity for 64,000 measured values
Large display with alarm information
Key pad with 4 keys, external start, alarm reset, measured value and alarm scroll
1 digital input
DB15 multifunction connection with alarm output and RS232
Direct printout of measured values and alarm data at printer
   
Ecolog TH1 with white housing Part No.: 2423-W
Ecolog TH1 EEX with approval for EEX zone 1 Part No.: 2423-Ex
 
   
  Datalogger ECOLOG TH2  
Datalogger ECOLOG TH2 Part No.: 2426
 
   
For 2 external, calibrated and exchangeable humidity and temperature probes -35°C ..+70°C; 0% ..100% rH (Part No.: 3087)
Memory capacity for 64,000 measured values
Large display with alarm information
Key pad with 4 keys, external start, alarm reset, measured value and alarm scroll
1 digital input
DB15 multifunction connection with alarm output and RS232
Direct printout of measured values and alarm data at printer
   
Ecolog TH2 with white housing Part No.: 2426-W
Ecolog TH2 EEX with approval for EEX zone 1 Part No.: 2426-Ex
 
  Datalogger ECOLOG TN2  
Datalogger ECOLOG TN2 Part No.: 2420
 
   
For 2 NTC probes -50°C..+140°C / -35°C..+55°C (with integrated temperature probe)
Memory capacity for 64,000 measured values
Large display with alarm information
DB15 multifunction connection with with alarm output and RS 232
External start / alarm reset / InPos recognition (with special connectors)
No keys, no direct printout
   
Ecolog TN2 with white housing Part No.: 2420-W
Ecolog TN2 EEX with approval for EEX zone 1 Part No.: 2420-Ex
 
  Datalogger ECOLOG TN3-P  
Datalogger ECOLOG TN3-P Part No.: 2420-P
 
   
For 3 NTC probes -50°C..+140°C / -35°C..+55°C (with integrated temperature probe)
Memory capacity for 64,000 measured values
Large display with alarm information
DB15 multifunction connection with alarm output and RS232
External start / alarm reset / InPos recognition (with special connectors)
Automatic printout of measured values at printer
No keys
   
Ecolog TN3-P with white housing Part No.: 2420-PW
Ecolog TN3-P EEX with approval for EEX zone 1 Part No.: 2420-PEx
 

  Datalogger ECOLOG TN4  
Datalogger ECOLOG TN4 Part No.: 2421
 
   
For 4 NTC probes -50°C..+140°C
Memory capacity for 64,000 measured values
Large display with alarm information
Key pad with 4 keys
External start, alarm reset, measured value and alarm scroll
2 digital inputs
DB15 multifunction connection with alarm output and RS232
Direct printout of measured values and alarm data at printer
   
Ecolog TN4 with white housing Part No.: 2421-W
Ecolog TN4 EEX with approval for EEX zone 1 Part No.: 2421-Ex
 
  Datalogger ECOLOG TN4-L  
Datalogger ECOLOG TN4-L Part No.: 2422
 
   
For 4 NTC probes -50°C..+140°C with LEMO connector
Memory capacity for 64,000 measured values
Large display with alarm information
Key pad with 4 keys
External start, alarm reset, measured value and alarm scroll
2 digital inputs
DB15 multifunction connection with alarm output and RS232
Direct printout of measured values and alarm data at printer
   
Ecolog TNç-L with white housing Part No.: 2422-W
Ecolog TN4-L EEX with approval for EEX zone 1 Part No.: 2422-Ex
 
  Datalogger ECOLOG TP2
Datalogger ECOLOG TP4-L
 
Datalogger ECOLOG TP2 or TP4-L  
 
   
TP2: For 2 PT100 probes in 4-wire system at DB15 connector Part No.: 2425-2T
TP4-L: For 4 PT100 probes in 4-wire system at LEMO connector Part No.: 2425
PT100 probes :-200°C..+550°C
Memory capacity for 64,000 measured values
Large display with alarm information
Key pad with 4 keys
External start, alarm reset, measured value and alarm scroll
1 digital input
DB15 multifunction connection with alarm output and RS232
Direct printout of measured values and alarm data at printer
 
Ecolog TP2 with white housing Part No.: 2425-2TW
Ecolog TP2 EEX with approval for EEX zone 1 Part No.: 2425-2TEx
Ecolog TP4-L with white housing Part No.: 2425-W
Ecolog TP4-L EEX with approval for EEX zone 1 Part No.: 2425-Ex
 
       
  Copyright © ELPRO / INT.GUNDULA.CH
Last changes: 28.04.06