Acceptance report after
commissioning of heating system |
|
| |
|
The supply and return temperatures at the
pipes below the insulation are measured. In addition, the outdoor and room
temperatures are recorded. |
|
| |
|
Material: |
|
| |
|
| 1x |
ECOLOG TN4-L Datenlogger
LEMO connector |
2422 |
| 2x |
Temperature probe NTC
drop probe |
3055-S03 |
| 1x |
Temperature probe NTC
-50°C..+140°C |
3090-S05 |
| 1x |
Temperature probe NTC
-50°C..+140°C |
3090-S15 |
 |
|
|
|
|
 |
|
|
|
|
|
 |
 |
|
|
|
 |
| |
 |
|
Acceptance of work, final
inspection report for customer |
|
| |
|
Subsequent to optimization of air conditioning
and heating systems, humidity and temperature are recorded in various rooms. |
|
| |
|
Material: |
|
| |
|
| 1x |
ECOLOG TH1 datalogger
with one-year memory capacity |
2423 |
| 1x |
ECOLOG TN2 datalogger |
2420 |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
Building drying in concrete
buildings, humidity and temperature |
|
| |
|
The room climate condition is recorded with
the integrated probe. The humidity in the concrete is measured in a bore
hole D=15mm. |
|
| |
|
Material: |
|
| |
|
| 1x |
ECOLOG TH1 datalogger
with one-year memory capacity |
2423 |
| 1x |
Plug-on universal probe
humidity/temperature |
3087 |
| 1x |
Extension cable for ECOLOG
THx |
3215-S05 |
| 1x |
Intermediate piece for
ECOLOG THx |
3215-DX |
| 1x |
Bracket can be locked |
2804-E |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
 |
| |
 |
|
Measuring system for comfort
documentation |
|
| |
|
The complete system measures and documents
all relevant climatic parameter needed for acceptance reports (ambient temperature,
rel. humidity, low air flows, thermal radiation). The system is handy and
therefore can be moved easily. As the datalogger is operating autonomously,
only sensor power supply is needed.
|
|
| |
|
Material: |
|
| |
|
| 1x |
HOTBOX SE universal datalogger |
2501 |
| 1x |
Hygroclip sensor humidity
/ temperature |
3088-A |
| 1x |
Globe thermometer for
measuring thermal radiation |
3091-GLO |
| 1x |
Air flow sensor, omni-directional,
0.01 - 1 m/s |
3264-F |
| 1x |
Tripod for mounting sensor,
datalogger and accessories |
2804-STA |
 |
|
|
|
|
 |
|
|
|
 |
|
 |
 |
|
|
|
|
| |
 |
|
Pressure recording at compressor |
|
| |
|
For optimization, high pressure, low pressure
and two temperatures are recorded simultaneously. |
|
| |
|
Material: |
|
| |
|
| 1x |
HOTBOX SE universal datalogger |
2501 |
| 1x |
Pressure sensor -1..9
bar |
3280-A |
| 1x |
Pressure sensor -1..24
bar |
3280-B |
| 1x |
Connector for 2 pressure
transmitters |
2540-P5 |
| 1x |
Mounting for 1-2 sensor
at connector |
2540-B |
| 2x |
NTC temperature sensor
-50°..140°C |
3055-L03 |
| 1x |
Connector for 2 NTC sensors |
2540-P4 |
| 1x |
Mounting for 1-2 sensor
at connector |
2540-B |
 |
|
|
|
|
 |
|
|
|
|
| |
Copyright © ELPRO / INT.GUNDULA.CH
Last changes: 24.08.05
Contact: |
|
|
|
 |
|
|
|
|